CPL - Chalmers Publication Library
| Utbildning | Forskning | Styrkeområden | Om Chalmers | In English In English Ej inloggad.

Percutaneous versus transcutaneous bone conduction implant system: a feasibility study on a cadaver head.

Bo Håkansson (Institutionen för signaler och system, Medicinska signaler och system) ; Måns Eeg-Olofsson ; Sabine Reinfeldt (Institutionen för signaler och system, Medicinska signaler och system) ; Stefan Stenfelt ; Gösta Granström
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology (1537-4505). Vol. 29 (2008), 8, p. 1132-9.
[Artikel, refereegranskad vetenskaplig]

OBJECTIVE: Percutaneous bone-anchored hearing aid (BAHA) is an important rehabilitation alternative for patients who have conductive or mixed hearing loss. However, these devices use a percutaneous and bone-anchored implant that has some drawbacks reported. A transcutaneous bone conduction implant system (BCI) is proposed as an alternative to the percutaneous system because it leaves the skin intact. The BCI transmits the signal to a permanently implanted transducer with an induction loop system through the intact skin. The aim of this study was to compare the electroacoustic performance of the BAHA Classic-300 with a full-scale BCI on a cadaver head in a sound field. The BCI comprised the audio processor of the vibrant sound bridge connected to a balanced vibration transducer (balanced electromagnetic separation transducer). METHODS: Implants with snap abutments were placed in the parietal bone (Classic-300) and 15-mm deep in the temporal bone (BCI). The vibration responses at the ipsilateral and contralateral cochlear promontories were measured with a laser Doppler vibrometer, with the beam aimed through the ear canal. RESULTS: Results show that the BCI produces approximately 5 dB higher maximum output level and has a slightly lower distortion than the Classic-300 at the ipsilateral promontorium at speech frequencies. At the contralateral promontorium, the maximum output level was considerably lower for the BCI than for the Classic-300 except in the 1-2 kHz range, where it was similar. CONCLUSION: Present results support the proposal that a BCI system can be a realistic alternative to a BAHA.

Nyckelord: Implantable bone conduction hearing aid



Denna post skapades 2009-02-04. Senast ändrad 2015-07-28.
CPL Pubid: 89598

 

Läs direkt!


Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för signaler och system, Medicinska signaler och system
Institutionen för kliniska vetenskaper, sektionen för hud, plastik och öron (2006-2009)

Ämnesområden

Otoneurologi

Chalmers infrastruktur