Reversed air staging - a method for reduction of N2O emissions from fluidized bed combustion of coal

Anders Lyngfelt (Institutionen för energiomvandling) ; Lars-Erik Åmand (Institutionen för energiomvandling) ; Bo Leckner (Institutionen för energiomvandling)
Fuel Vol. 77 (1998), 9-10, p. 953-959.
[Artikel, refereegranskad vetenskaplig]

Reversed air staging, a method for reduction of N2O emissions, was studied in a 12 MW circulating fluidized bed boiler. The effect of combustor air-ratio, bed temperature, load and limestone addition ratio was investigated. The results indicate that if only the air distribution is changed, the emission of N2O can be decreased to one fourth compared to normal air staging at a temperature of 850°C, with maintained low emissions of NO,´SO2 and CO. With increased bed temperature, 870°C, in combination with increased limestone addition, from Ca/S molar ratio = 3 to 4, it was possible to reduce N2O by 90 vol% with low emissions of NO, SO2 and CO. The method was less efficient at low load, because of the lower cyclone temperature. Also the effect of redistribution of some of the air added in the cyclone outlet to the cyclone inlet was studied. This did not, however, give any improvement in the boiler used compared to adding all of the air in the cyclone outlet. There was no significant difference in combustion efficiency between reversed air staging and normal air staging.

Nyckelord: N2O, fluidized-bed, combustion



Den här publikationen ingår i följande styrkeområden:

Läs mer om Chalmers styrkeområden  

Denna post skapades 2006-09-19. Senast ändrad 2016-08-15.
CPL Pubid: 5023

 

Läs direkt!

Lokal fulltext (fritt tillgänglig)


Institutioner (Chalmers)

Institutionen för energiomvandling (1900-2003)

Ämnesområden

Energi
Hållbar utveckling
Termisk energiteknik
Miljöteknik

Chalmers infrastruktur

Chalmers Kraftcentral (CK)