Rain intrusion rates at façade details - A summary of results from four laboratory studies

Lars Olsson (Institutionen för arkitektur och samhällsbyggnadsteknik)
Energy Procedia: 11th Nordic Symposium on Building Physics, NSB 2017; Trondheim; Norway; 11 June 2017 through 14 June 2017 (18766102). Vol. 132 (2017), p. 387-392.
[Konferensbidrag, refereegranskat]

More knowledge and realistic data on inward leakage is needed not only to better understand and confirm rain resistance of different facades, but also to carry out reliable theoretical moisture risk assessments of façade details in external walls. This article is an attempt to highlight amounts of expected leakage based on four laboratory studies. The results show that under heavy driving rain conditions, there may be continuous point leakage of significant volumes of water (0,01-0,05 l/min) in small invisible deficiencies, and corresponds to up to 2% of the applied water load. The leakage rate also depends, more or less, on the size, position and geometry of the deficiency, cumulative runoff rates, size of projecting details and surface properties.

Nyckelord: building envelope; Driving rain; EN 12865; rain intrusion; risk assessment; wall; water lekage; window



Denna post skapades 2017-12-22.
CPL Pubid: 254062

 

Läs direkt!


Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för arkitektur och samhällsbyggnadsteknik

Ämnesområden

Samhällsbyggnadsteknik

Chalmers infrastruktur