Drying potential of cold attic using natural and controlled ventilation in different Swedish climates

Carl-Eric Hagentoft (Institutionen för bygg- och miljöteknik, Byggnadsteknologi) ; Angela Sasic Kalagasidis (Institutionen för bygg- och miljöteknik, Byggnadsteknologi)
Procedia Engineering 146 (1877-7058). Vol. 146 (2016), p. 2-7.
[Konferensbidrag, refereegranskat]

Problems with high humidity levels and mold growth in cold attics have been increasing over the last few years. The high humidity levels are to a large extent a consequence of the increasing demand on energy efficiency. Houses are frequently retrofitted with additional attic insulation, which leads to a colder attic space and hence a higher humidity. Replacing furnace heating by heat pumps or district heat may also lead to problem. Also newly built attics have problems. The quite novel technical solution with controlled mechanical ventilation of the attic is generally estimated to be risk free in Swedish climate. With controlled mechanical ventilation the attic is intentionally ventilated only when the inflowing air is drying out the attic, otherwise it is shut off. The drying potential of controlled ventilation is analyzed for different climate zone in order to map the relative efficiency compared with traditional natural ventilated attics.

Nyckelord: Attic, moisture, drying, natural ventilation, controlled ventilation, climate



Den här publikationen ingår i följande styrkeområden:

Läs mer om Chalmers styrkeområden  

Denna post skapades 2016-07-08. Senast ändrad 2016-07-08.
CPL Pubid: 239223

 

Läs direkt!

Lokal fulltext (fritt tillgänglig)

Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för bygg- och miljöteknik, Byggnadsteknologi

Ämnesområden

Building Futures
Byggnadsteknik

Chalmers infrastruktur