Particulate emissions from small-scale biomass combustion

Linda Johansson ; C. Tullin ; Bo Leckner (Institutionen för energiomvandling)
Aerosols from Biomass Combustion p. 87-92. (2001)
[Konferensbidrag, refereegranskat]

An increased use of small-scale biomass combustion can result in higher ambient concentrations of particulate matter. The objective with this investigation is to characterise the emissions of particulates as well as gases from smaller district heating plants (2-3 MW) where the particle separation is limited to cyclones. The particle measurements were performed downstream the cyclones. The particle number size distributions were found to be dominated by submicron particles with peaks in the size range of 0.1-0.3 µm. The dust emissions were in the range of 60-200 mg/mn3 at 13% CO2. The number concentrations during normal operation are 107per cm3. The influence of load, excess air and fuel quality is discussed. In addition, results are reported for gaseous pollutants, i.e. CO/CO2, THC (total hydrocarbons), CH4 (methane), C2H4 (ethene), NOx and NH3 (ammonia).

Nyckelord: district-heating boiler, biomass, small-scale, particulate emissions, particle size distribution, gas emissions


Information och kopior --Verenum, Langmauerstrasse 109, CH - 8006 Zürich, verenum@access.ch --ENET, Egnacherstrasse 69, CH - 9320 Arbon, enet@temas.ch --IEA Bioenergy Task 32, c/o TNO-MEP, P.O. Box 342, NL - 7300 AH Apeldoorn http://www.ieabioenergy-task32.com



Den här publikationen ingår i följande styrkeområden:

Läs mer om Chalmers styrkeområden  

Denna post skapades 2016-06-30. Senast ändrad 2016-08-15.
CPL Pubid: 238726

 

Institutioner (Chalmers)

Institutionen för energiomvandling (1900-2003)

Ämnesområden

Energi
Termisk energiteknik

Chalmers infrastruktur