Evaluation of long-term performance of VIPs

Pär Johansson (Institutionen för bygg- och miljöteknik, Byggnadsteknologi) ; Bijan Adl-Zarrabi (Institutionen för bygg- och miljöteknik, Byggnadsteknologi) ; Axel Berge (Institutionen för bygg- och miljöteknik, Byggnadsteknologi)
Energy Procedia: Proceedings of the 6th International Building Physics Conference, IBPC 2015 (1876-6102). Vol. 78 (2015), p. 388-393.
[Konferensbidrag, refereegranskat]

Apart from the higher initial cost for using vacuum insulation panels (VIPs) in buildings there is still hesitation among architects and engineers whether these materials will withstand long-term use in buildings with a service life of 80-100 years. To evaluate the long-term performance, further investigations are needed. VIPs have been used in buildings since the 1990s and there already exists experience from using them in various applications. This paper presents the experiences from two field studies of a previously non-insulated wall with VIPs and a district heating pipe with hybrid VIP/PUR insulation. Measurements of the relative humidity in the wall showed that there is low risk of condensation in the VIP layer. Temperature measurements in the wall during the period 2010 to 2015 show no signs of deterioration of the VIPs. The same conclusion was made based on the temperature profiles in the district heating pipes during the period 2012 to 2015. The measurements are on-going to determine the long-term performance of the VIPs in different applications.

Nyckelord: retrofitting, listed building, vacuum insulation panel, field study, measurement



Den här publikationen ingår i följande styrkeområden:

Läs mer om Chalmers styrkeområden  

Denna post skapades 2015-07-03. Senast ändrad 2016-05-13.
CPL Pubid: 219345

 

Läs direkt!

Lokal fulltext (fritt tillgänglig)

Länk till annan sajt (kan kräva inloggning)