CPL - Chalmers Publication Library
| Utbildning | Forskning | Styrkeområden | Om Chalmers | In English In English Ej inloggad.

Performance of timing Resistive Plate Chambers with protons from 200 to 800 MeV

J. Machado ; J. Adamczewski-Musch ; A. Blanco ; K. Boretzky ; P. Cabanelas ; L. Cartegni ; R. Ferreira Marques ; P. Fonte ; J. Fruehauf ; D. Galaviz ; M. Heil ; A. Henriques ; G. Ickert ; D. Körper ; L. Lopes ; M. Palka ; A. Pereira ; D. Rossi ; H. Simon ; P. Teubig ; M. Traxler ; P. Velho ; S. Altstadt ; L. Atar ; T. Aumann ; D. Bemmerer ; C. Caesar ; Alexandre Charpy (Institutionen för fundamental fysik) ; Z. Elekes ; E. Fiori ; I. Gasparic ; J. Gerbig ; K. Göbel ; T. Heftrich ; M. Heine ; Andreas Martin Heinz (Institutionen för fundamental fysik) ; M. Holl ; A. Ignatov ; J. Isaak ; Håkan T. Johansson (Institutionen för fundamental fysik) ; A. Kelic-Heil ; C. Lederer ; Simon Lindberg (Institutionen för fundamental fysik) ; B. Löher ; J. Marganiec ; Mikael Mårtensson (Institutionen för fundamental fysik) ; Thomas Nilsson (Institutionen för fundamental fysik) ; V. Panin ; S. Paschalis ; M. Petri ; R. Plag ; M. Pohl ; G. Rastrepina ; R. Reifarth ; T. P. Reinhardt ; M. Röder ; D. Savran ; H. Scheit ; P. Schrock ; J. Silva ; D. Stach ; Fredrik Strannerdahl (Institutionen för fundamental fysik) ; Ronja Thies (Institutionen för fundamental fysik) ; A. Wagner ; F. Wamers ; M. Weigand
Journal of Instrumentation (1748-0221). Vol. 10 (2015), 1, p. C01043.
[Artikel, refereegranskad vetenskaplig]

A prototype composed of four resistive plate chamber layers has been exposed to quasi-monoenergetic protons produced from a deuteron beam of varying energy (200 to 800 AMeV) in experiment S406 at GSI, Darmstadt, Germany. The aim of the experiment is to characterize the response of the prototype to protons in this energy range, which deposit from 1.75 to 6 times more energy than minimum ionizing particles. Each layer, with an active area of about 2000 × 500 mm 2 , is made of modules containing the active gaps, all in multigap construction. Each gap is defined by 0.3 mm nylon mono-filaments positioned between 2.85 mm thick float glass electrodes. The modules are operated in avalanche mode with a non-flammable gas mixture composed of 90% C 2 H 2 F 4 and 10% SF 6 . The signals are readout by a pick-up electrode formed by 15 copper strips (per layer), spaced at a pitch of 30 mm, connected at both sides to timing front end electronics. Results show an uniform efficiency close to 100% along with a timing resolution of around 60 ps on the entire 2000 × 500 mm 2 area.

Nyckelord: Instrumentation and methods for time-of-flight (TOF) spectroscopy; Particle detectors; Resistive-plate chambers



Denna post skapades 2015-02-10. Senast ändrad 2015-11-16.
CPL Pubid: 212380

 

Läs direkt!


Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för fundamental fysik (2005-2015)

Ämnesområden

Fysik
Subatomär fysik
Kärnfysik
Mellanenergifysik
Acceleratorfysik och instrumentering

Chalmers infrastruktur