Deposits on heat transfer tubes during co-combustion of biofuels and sewage sludge

Lars-Erik Åmand (Institutionen för energi och miljö, Energiteknik) ; Bo Leckner (Institutionen för energi och miljö, Energiteknik) ; David Eskilsson ; Claes Tullin
Fuel (0016-2361). Vol. 85 (2006), 10-11, p. 1313-1322.
[Artikel, refereegranskad vetenskaplig]

Potassium together with chlorine is the principal species that causes undesirable deposits and eventually corrosion on heat exchanger tubes in boilers fired with bio and waste fuels. It is shown here by tests in a circulating fluidized bed boiler that co-combustion of biomass with another fuel, in this case municipal sewage sludge, can remove or considerably reduce such deposits at the same time as the amount of submicron particles deceases radically. There may be at least four reasons for the beneficial impact of the additional fuel: (1) sulphur in the fuel may react with potassium, producing sulphate and gaseous hydrogen chloride which are less harmful, (2) potassium chloride may be removed by condensation on fly ash particles added with the other fuel, or (3) potassium in gaseous form may react with alumino-silicates provided by the additional fuel, and finally, (4) deposits may be mechanically removed by the increased ash flows caused by the additional fuel. In one of these ways or a combination of them, formation of deposits on tubes by potassium chloride could be avoided or alleviated.

Nyckelord: Biofuel, Sewage sludge, Deposits,Corrosion,Fluidized bed



Den här publikationen ingår i följande styrkeområden:

Läs mer om Chalmers styrkeområden  

Denna post skapades 2006-09-11. Senast ändrad 2016-08-30.
CPL Pubid: 20436

 

Läs direkt!

Lokal fulltext (fritt tillgänglig)