CO2 sensors for occupancy estimations: Potential in building automation applications

Mattias Gruber (Institutionen för energi och miljö, Installationsteknik) ; Anders Trüschel (Institutionen för energi och miljö, Installationsteknik) ; Jan-Olof Dalenbäck (Institutionen för energi och miljö, Installationsteknik)
Energy and Buildings (0378-7788). Vol. 84 (2014), p. 548-556.
[Artikel, refereegranskad vetenskaplig]

It is well established that model-based controllers with an integrated control model and information about indoor climate disturbances have the ability to drastically improve the performance of building automation systems. In offices, occupancy is one of the most important disturbances to account for in this context, but the available methods for accurately determining the number of people are commonly too complex for considering at most sites. However, since model-based controllers can be made robust, input deficiencies can to a certain degree be compensated for, and in this work, a two step procedure was applied to investigate the potential of utilizing simplified estimations generated from CO2 sensor responses. First, the expected time delay and error of such estimations were derived experimentally for various occupancy changes and ventilation flow rates. Next, an office site was simulated and the occupancy information used by a model-based controller for ventilation control was stepwise subjected to various errors and time delays by considering the expected values as references. The results showed that the estimations in many case were sufficient for achieving a high control performance, but beyond a certain level, the deficiencies could only be met by an increased complexity of the controller.

Nyckelord: Heating, ventilation and air-conditioning; Office buildings; Building automation system; Indoor air quality; Occupancy estimations; Information deficiencies; Controller robustness; Model predictive control; Predictive control



Den här publikationen ingår i följande styrkeområden:

Läs mer om Chalmers styrkeområden  

Denna post skapades 2014-10-15. Senast ändrad 2015-05-27.
CPL Pubid: 204345

 

Läs direkt!


Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för energi och miljö, Installationsteknik (2005-2014)

Ämnesområden

Energi
Energiteknik

Chalmers infrastruktur

Relaterade publikationer

Denna publikation ingår i:


Energy efficient indoor climate control - A practical approach for enhanced implementability