Synchronization at startup and stable rotation reversal of sensorless nonsalient PMSM drives

Magnus Jansson ; Lennart Harnefors ; Oskar Wallmark (Institutionen för energi och miljö, Elteknik) ; Mats Leksell
IEEE Transactions on Industrial Electronics Vol. 53 (2006), 2, p. 379-387.
[Artikel, refereegranskad vetenskaplig]

In this paper, a variant of the well-known "voltage model" is applied to rotor position estimation for sensorless control of nonsalient permanent-magnet synchronous motors (PMSMs). Particular focus is on a low-speed operation. It is shown that a guaranteed synchronization from any initial rotor position and stable reversal of rotation can be accomplished, in both cases under load. Stable rotation reversal is accomplished by making the estimator insensitive to the stator resistance. It is also shown that the closed-loop speed dynamics are similar to those of a sensored drive for speeds above approximately 0.1 per unit, provided that the model stator inductance is underestimated. Experimental results support the theory.

Nyckelord: Permanent-magnet synchronous motor, position estimation, sensorless control, stability analysis



Denna post skapades 2006-08-25.
CPL Pubid: 19069

 

Läs direkt!


Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för energi och miljö, Elteknik (2005-2017)

Ämnesområden

Elkraftteknik

Chalmers infrastruktur