CPL - Chalmers Publication Library
| Utbildning | Forskning | Styrkeområden | Om Chalmers | In English In English Ej inloggad.

PERMANENT MAGNET SYNCHRONOUS GENERATOR INTER TURN FAULT IDENTIFICATION USING STATOR CURRENT ANALYSIS

Joachim Härsjö (Svenskt VindkraftsTekniskt Centrum (SWPTC)) ; Massimo Bongiorno (Svenskt VindkraftsTekniskt Centrum (SWPTC)) ; Stefan Lundberg ; Ola Carlson (Svenskt VindkraftsTekniskt Centrum (SWPTC))
9th PhD Seminar on Wind Energy in Europe, EAWE (2013)
[Konferensbidrag, refereegranskat]

A three phase permanent magnet synchronous generator is modeled both as a FEM model and an analytically model with an additional fourth winding that represents the faulty part of the machine. The faulty part is described as a fraction of the healthy machine. The proposed method can be used for multi pole machines as a general method for calculating the inductances is shown. Simulations show that the largest contributing parameter is the fault resistance, i.e. the contact resistance of the inter turn fault. FEM and analytical simulations show similar results but with amplitude an amplitude difference.



Den här publikationen ingår i följande styrkeområden:

Läs mer om Chalmers styrkeområden  

Denna post skapades 2013-10-15.
CPL Pubid: 185260

 

Institutioner (Chalmers)

Svenskt VindkraftsTekniskt Centrum (SWPTC)

Ämnesområden

Energi
Hållbar utveckling
Elkraftteknik