CPL - Chalmers Publication Library
| Utbildning | Forskning | Styrkeområden | Om Chalmers | In English In English Ej inloggad.

A virus biosensor with single virus-particle sensitivity based on fluorescent vesicle labels and equilibrium fluctuation analysis

Marta Bally (Institutionen för teknisk fysik, Biologisk fysik) ; Mauritz Graule (Institutionen för teknisk fysik, Biologisk fysik) ; F. Parra ; Göran Larson ; Fredrik Höök (Institutionen för teknisk fysik, Biologisk fysik)
Biointerphases (1559-4106). Vol. 8 (2013), p. Article number: 4.
[Artikel, refereegranskad vetenskaplig]

Biosensors allowing for the rapid and sensitive detection of viral pathogens in environmental or clinical samples are urgently needed to prevent disease outbreaks and spreading. We present a bioanalytical assay for the detection of whole viral particles with single virus sensitivity. Specifically, we focus on the detection of human norovirus, a highly infectious virus causing gastroenteritis. In our assay configuration, virus-like particles are captured onto a supported lipid bilayer containing a virus-specific glycolipid and detected after recognition by a glycolipid-containing fluorescent vesicle. Read-out is performed after illumination of the vesicle labels by total internal reflection fluorescence microscopy. This allows for visualization of individual vesicles and for recording of their binding kinetics under equilibrium conditions (equilibrium fluctuation analysis), as demonstrated previously. In this work we extend the concept and demonstrate that this simple assay setup can be used as a bioanalytical assay for the detection of virus particles at a limit of detection of 16 fM. Furthermore, we demonstrate how the analysis of the single vesicle-virus-like particle interaction dynamics can contribute to increase the accuracy and sensitivity of the assay by discriminating specific from non-specific binding events. This method is suggested to be generally applicable, provided that these events display different interaction kinetics.

Nyckelord: Virus detection, Biosensor, Norovirus, Glycosphingolipids, Phospholipid vesicle, Nanoscale label, Fluorescence, Liposome, Virus-like particle



Denna post skapades 2013-03-15. Senast ändrad 2016-05-13.
CPL Pubid: 174693

 

Läs direkt!

Lokal fulltext (fritt tillgänglig)

Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för teknisk fysik, Biologisk fysik (2007-2015)
Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin (GU)

Ämnesområden

Kemi

Chalmers infrastruktur