LaBr3(Ce):LaCl3(Ce) Phoswich with pulse shape analysis for high energy gamma-ray and proton identification

Olof Tengblad ; Thomas Nilsson (Institutionen för fundamental fysik, Subatomär fysik) ; E. Nácher ; Håkan T. Johansson (Institutionen för fundamental fysik, Subatomär fysik) ; J. A. Briz ; M. Carmona-Gallardo ; C. Cruz ; V. Gugliermina ; A. Perea ; J. Sanchez del Rio ; M. Turrión Nieves ; Johan Bergström (Institutionen för fundamental fysik, Subatomär fysik) ; Erik Blomberg (Institutionen för fundamental fysik, Subatomär fysik) ; Andreas Bülling (Institutionen för fundamental fysik, Subatomär fysik) ; Erik Gallneby (Institutionen för fundamental fysik, Subatomär fysik) ; Julius Hagdahl (Institutionen för fundamental fysik, Subatomär fysik) ; Linnea Jansson (Institutionen för fundamental fysik, Subatomär fysik) ; Klas Jareteg (Institutionen för fundamental fysik, Subatomär fysik) ; Robert Masgren (Institutionen för fundamental fysik, Subatomär fysik) ; Martin Nordström (Institutionen för fundamental fysik, Subatomär fysik) ; Gustav Risting (Institutionen för fundamental fysik, Subatomär fysik) ; Shervin Shojaee (Institutionen för fundamental fysik, Subatomär fysik) ; Henry Wittler (Institutionen för fundamental fysik, Subatomär fysik)
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment (0168-9002). Vol. 704 (2013), 0, p. 19-26.
[Artikel, refereegranskad vetenskaplig]

A novel Phoswich design based on new generation scintillator crystals is presented. The detector composed from a combination of a LaBr3(Ce) with a LaCl3(Ce) crystal in one cylinder coupled to a photo multiplier tube has been tested both for incident gamma rays in the range of 0.3–6 MeV, as well as for high energy protons in the range 120–180 MeV. The Phoswich assembly has not significantly deteriorated the energy resolution, which for 662 KeV gamma rays gives a resolution of 4.5%, while for high energy protons (Ep=180 MeV) an energy resolution of 1% was obtained. It is shown that the signals from the two crystals can be separated in an event by event based mode. Using direct digitizing of the detector pulse an off-line pulse-shape analysis was performed built either on a total to tail or total to pulse height method in order to fully identify the incoming radiation. Our aim with this R&D is to in the future build a detector which is able to detect with good efficiency and resolution over a wide energy range; 0.1–30 MeV gamma rays and 20–400 MeV protons. Monte Carlo simulations made in order to design the next prototype are presented.

Nyckelord: Phoswich scintillator, Gamma calorimeter, LaBr 3 (Ce), LaCl 3 (Ce), Pulse shape analysis



Denna post skapades 2013-01-03. Senast ändrad 2016-10-04.
CPL Pubid: 169078

 

Läs direkt!


Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för fundamental fysik, Subatomär fysik (2005-2013)

Ämnesområden

Kärnfysik
Acceleratorfysik och instrumentering