CPL - Chalmers Publication Library
| Utbildning | Forskning | Styrkeområden | Om Chalmers | In English In English Ej inloggad.

Decay of Bacteroidales Genetic Markers in Relation to Traditional Fecal Indicators for Water Quality Modeling of Drinking Water Sources

Ekaterina Sokolova (Institutionen för bygg- och miljöteknik, Vatten Miljö Teknik) ; Johan Åström (Institutionen för bygg- och miljöteknik, Vatten Miljö Teknik) ; Thomas J. R. Pettersson (Institutionen för bygg- och miljöteknik, Vatten Miljö Teknik) ; Olof Bergstedt (Institutionen för bygg- och miljöteknik, Vatten Miljö Teknik) ; Malte Hermansson
Environmental Science and Technology (0013-936X). Vol. 46 (2012), 2, p. 892-900.
[Artikel, refereegranskad vetenskaplig]

The implementation of microbial fecal source tracking (MST) methods in drinking water management is limited by the lack of knowledge on the transport and decay of host-specific genetic markers in water sources. To address these limitations, the decay and transport of human (BacH) and ruminant (BacR) fecal Bacteroidales 16S rRNA genetic markers in a drinking water source (Lake Radasjon in Sweden) were simulated using a microbiological model coupled to a three-dimensional hydrodynamic model. The microbiological model was calibrated using data from outdoor microcosm trials performed in March, August, and November 2010 to determine the decay of BacH and BacR markers in relation to traditional fecal indicators. The microcosm trials indicated that the persistence of BacH and BacR in the microcosms was not significantly different from the persistence of traditional fecal indicators. The modeling of BacH and BacR transport within the lake illustrated that the highest levels of genetic markers at the raw water intakes were associated with human fecal sources (onsite sewers and emergency sewer overflow). This novel modeling approach improves the interpretation of MST data, especially when fecal pollution from the same host group is released into the water source from different sites in the catchment.

Nyckelord: Bacteroidales markers, hydrodynamic modelling, drinking water quality, microcosm trials



Denna post skapades 2012-01-25. Senast ändrad 2014-09-17.
CPL Pubid: 154413

 

Läs direkt!

Lokal fulltext (fritt tillgänglig)

Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för bygg- och miljöteknik, Vatten Miljö Teknik
Institutionen för kemi och molekylärbiologi (GU)

Ämnesområden

Vattenteknik

Chalmers infrastruktur

Relaterade publikationer

Denna publikation ingår i:


Hydrodynamic modelling of microbial water quality in drinking water sources