Dependence of Sulphur Capture Performance on Air Staging in a 12 MW Circulating Fluidised Bed Boiler

Anders Lyngfelt (Institutionen för energiomvandling) ; Klas Bergqvist (Institutionen för energiomvandling) ; Filip Johnsson (Institutionen för energiomvandling) ; Lars-Erik Åmand (Institutionen för energiomvandling) ; Bo Leckner (Institutionen för energiomvandling)
Gas Cleaning at High Temperatures, Eds. R. Clift and J.P.K. Seville, Blackie Academic & Professional, Glasgow, ISBN 0 7514 0178 1. p. 470-491. (1993)
[Kapitel]

Three cases of air staging were examined in a 12 MW circulating fluidised bed boiler: i) no staging, ii} normal staging and iii) intensified staging. The conditions inside the combustion chamber were investigated by zirconia cell measurements of the oxygen partial pressure, 0.35, 0.65 and 8 m above the bottom air distributor plate. A significant effect of the degree of staging was seen in the two lower locations: At 0.65 m height the fraction of time under substoichiometric conditions was low in the no-staging case (2-35%), at normal staging it was 70-90%, whereas at intensified staging it was 100Y.. At 0.35 m height, i.e. in the dense bed, a similar effect was seen, although the fraction of time under reducing conditions was lower. The fraction of time under reducing conditions was low in the top of the combustion chamber in all three cases . The increase in the fraction of time under reducing conditions with a higher degree of staging is associated with a decrease in sulphur capture. It is assumed that a release of SO2 from CaSO4 takes place during the transitions between oxidising and reducing conditions. Thus, the rapid alternations between oxidising and reducing conditions, as seen with the zirconia cell, offer an explanation of the reductive decomposition and, accordingly, of the dependence of sulphur capture on temperature and on the extent of staging.

Nyckelord: Fluidized bed combustion, reversed air staging, nitrous oxide emissions, N2O



Den här publikationen ingår i följande styrkeområden:

Läs mer om Chalmers styrkeområden  

Denna post skapades 2011-11-14. Senast ändrad 2016-08-15.
CPL Pubid: 148436

 

Läs direkt!

Lokal fulltext (fritt tillgänglig)


Institutioner (Chalmers)

Institutionen för energiomvandling (1900-2003)

Ämnesområden

Energi
Hållbar utveckling
Teknisk mekanik
Termisk energiteknik

Chalmers infrastruktur

Chalmers Kraftcentral (CK)