Kinetic data of a promising oxygen carrier of NiO/NiAl(2)O(4) have been established from experiments in a small fluidized bed batch reactor using methane. The particles were prepared by spray-drying using commercially available raw material and selected as the best candidates from an earlier screening study. The particles clearly showed high reactivity, with a maximum gas yield between 86% and 93% in the temperature interval 750 degrees C to 950 degrees C when using a bed mass and a gas flow corresponding to only 6 kg/MW(fuel). A comparison of the reactivity with data from TGA experiments showed that the reactivity generally was faster in the batch fluidized bed in the investigated temperature interval. A simple reactor model using kinetic data from the batch fluidized bed reactor and the TGA predicted a minimum mass of 9-24 kg/MW(fuel) of oxygen carrier particles for full gas yield of methane to carbon dioxide in the fuel reactor. Comparison with experiments performed in a 10 and 120 kW CLC reactor with the same type of oxygen carrier showed that even when employing 13 to 50 times the amount of oxygen carrier theoretically needed for complete gas conversion, full gas yield was not obtained in the circulating systems. Hence it is of great importance to consider the fluid dynamics and gas-solid contact when modeling the fuel reactor of a chemical-looping combustor.

Nyckelord: Chemical-looping combustion, NiO, Methane, Oxygen carrier, Kinetics, Fluidized bed, reactor system, particles, reduction, kinetics, behavior, methane, fuel, nio



Denna post skapades 2011-09-08. Senast ändrad 2016-11-07.
CPL Pubid: 145934

 

Läs direkt!


Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för energi och miljö, Energiteknik (2005-2017)
Institutionen för kemi- och bioteknik, Oorganisk miljökemi (2005-2014)

Ämnesområden

Kemi

Chalmers infrastruktur