CPL - Chalmers Publication Library
| Utbildning | Forskning | Styrkeområden | Om Chalmers | In English In English Ej inloggad.

Transient thermal conductivity of flexible district heating twin pipes

Charlotte Reidhav (Institutionen för bygg- och miljöteknik, Byggnadsteknologi) ; Johan Claesson (Institutionen för bygg- och miljöteknik, Byggnadsteknologi)
12th International Symposium on District Heating and Cooling; Tallinn; 5-7 September 2010 p. 90-95. (2010)
[Konferensbidrag, övrigt]

The standardized methods to measure the thermal conductivity of straight district heating pipes are not applicable on flexible district heating pipes. This paper presents a transient method determining the temperature dependent thermal conductivity of flexible twin pipes. A transient method to determine the temperaturedependent thermal conductivity of flexible single district heating pipes is presented in this paper. A flexible pipe coil is immersed into cold water. Hot water is distributed in the coil. The temperature decline of the coil water is measured and calculated. Minimizing the difference between the calculated and measured temperatures gives λ(T) of the flexible polyurethane foam. The method gives small errors.



Denna post skapades 2011-04-12.
CPL Pubid: 138975

 

Institutioner (Chalmers)

Institutionen för bygg- och miljöteknik, Byggnadsteknologi

Ämnesområden

Byggnadsteknik

Chalmers infrastruktur