Magnetic Field From Spot Welding Equipment - Is the Basic Restriction Exceeded?

Mohammad Nadeem (Institutionen för elektromagnetik, Elektromagnetiska beräkningar) ; Yngve Hamnerius (Institutionen för signaler och system ; Institutionen för elektromagnetik, Bioeffekt) ; Kjell Hansson Mild ; Mikael Persson (Institutionen för elektromagnetik, Elektromagnetisk bio- och plasmafysik)
Bioelectromagnetics (0197-8462). Vol. 25 (2004), 4, p. 278-284.
[Artikel, refereegranskad vetenskaplig]

A point measurement of the magnetic field (MF) near a typical spot welding machine showed that the magnetic flux density was above the ICNIRP reference level. To investigate if the basic restrictions were exceeded, the induced body currents in a full 3D human model were calculated. It was found that at an operator position of 34 cm away from the machine the maximum induced current density was below the ICNIRP basic restriction. But if the operator was closer to the machine, the basic restriction was exceeded. An important finding of the present article is that the basic restriction can be exceeded although the MF spatially averaged over the whole body is well below the reference level.

Nyckelord: Exposure, welding, ICNIRP

Denna post skapades 2006-10-23. Senast ändrad 2013-05-22.
CPL Pubid: 12828


Läs direkt!

Länk till annan sajt (kan kräva inloggning)

Institutioner (Chalmers)

Institutionen för elektromagnetik, Elektromagnetiska beräkningar (1900-2004)
Institutionen för signaler och system
Institutionen för elektromagnetik, Bioeffekt (1900-2004)
Institutionen för elektromagnetik, Elektromagnetisk bio- och plasmafysik (1900-2004)


Elektronisk mät- och apparatteknik
Teknisk mekanik

Chalmers infrastruktur