Co-firing of coal and biomass in Circulating Fluidized Beds

Influence of scale comparing 50KW and 12 MW units

H. Häsä ; A. Tourunen ; J. Saastamoinen ; T. Jäntti ; Filip Johnsson (Institutionen för energi och miljö, Energiteknik) ; David Pallares (Institutionen för energi och miljö, Energiteknik)
6th European Conference on Coal Research and its Applications (2006)
[Konferensbidrag, refereegranskat]

To fulfil the development needs of OTSC CFB technology, a comprehensive understanding of CFB combustion processes needed to be achieved. Intensive research in laboratory, pilot and fullscale combustors is required to fulfil the abovementioned objectives.In order to study different process characteristics and verify measurements and simulations, experiments were carried out with different size reactors; VTT’s laboratory scale CFB reactor, VTT’s 50 kW pilot CFB reactor, Chalmers’ 12 MW CFB boiler, cold rig and with several commercial boilers.



Denna post skapades 2010-02-15. Senast ändrad 2010-04-27.
CPL Pubid: 112200

 

Institutioner (Chalmers)

Institutionen för energi och miljö, Energiteknik

Ämnesområden

Kemisk energiteknik