CPL - Chalmers Publication Library
| Utbildning | Forskning | Styrkeområden | Om Chalmers | In English In English Ej inloggad.

Water Vapor Radiometer for ALMA

Anders Emrich ; S. Andersson ; M. Wannerbratt ; Peter Sobis (Institutionen för mikroteknologi och nanovetenskap, Fysikalisk elektronik) ; Sergey Cherednichenko (Institutionen för mikroteknologi och nanovetenskap, Fysikalisk elektronik) ; David Runesson ; Terese Ekebrand ; M. Krus ; Christina Tegnander ; U. Krus
Proc. of 20th International Symposium on Space Terahertz Technology, Charlottesville, USA, 20-22 April, 2009 p. 174-177. (2009)
[Konferensbidrag, refereegranskat]

Radiometer for the ALMA project from scratch in 18 months and will deliver 50 units within the next 18 months. The radiometer includes an Optical Relay, Mounting Frame as well as the Radiometer core module. The radiometer core include optics and calibration system as well as a schottky mixer based frontend and a filterbank back-end. These subsystems are supported by a thermal management subsystem, control and communication subsystem as well as a power subsystem. The system and subsystems will be described in the paper.

Nyckelord: radiometer, ALMA, water vapor, Schottky diode, mixer, heterodyne receiver, quasioptics, submillimeter waves



Denna post skapades 2010-01-19.
CPL Pubid: 108860

 

Läs direkt!


Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för mikroteknologi och nanovetenskap, Fysikalisk elektronik (2007-2010)

Ämnesområden

Optik
Astronomi, astrofysik och kosmologi
Elektroteknik och elektronik

Chalmers infrastruktur

Relaterade publikationer

Denna publikation ingår i:


Subharmonic Sideband Separating Schottky Diode Mixer for Submillimetre Wave Applications


Advanced Schottky Diode Receiver Front-Ends for Terahertz Applications