Use of advanced composite curves for assessing cost-effective HEN retrofit I: Theory and concepts

Roger Nordman (Institutionen för energi och miljö, Värmeteknik och maskinlära) ; Thore Berntsson (Institutionen för energi och miljö, Värmeteknik och maskinlära)
Applied Thermal Engineering (1359-4311). Vol. 29 (2009), 2-3, p. 275-281.
[Artikel, refereegranskad vetenskaplig]

This paper presents the theory and concepts of a graphical method for heat exchanger network (HEN) retrofit that gives new insights about the complexity and possible solutions of different retrofit alternatives. The method uses knowledge about the placement of heaters/coolers in the existing HEN to evaluate the potential for cost-effective retrofit. One general result this method predicts is that the closer to the pinch the existing heaters/coolers are located, the higher the potential for cost-effective retrofit. Networks that are badly engineered from a grass-root perspective, prove to be a good basis for cost-effective retrofits.

Nyckelord: Pinch technology; Retrofit; Composite curves; Heat exchanger network



Denna post skapades 2010-01-18. Senast ändrad 2013-10-29.
CPL Pubid: 108663

 

Läs direkt!


Länk till annan sajt (kan kräva inloggning)


Institutioner (Chalmers)

Institutionen för energi och miljö, Värmeteknik och maskinlära (2005-2014)

Ämnesområden

Kemiteknik

Chalmers infrastruktur